MCB 2P 6A 10kA B Curve DIN Rail NB1-63H Chint
Chint NB1-63H 2P 6A MCB features 10kA breaking capacity, B-curve thermal-magnetic protection and DIN rail mount to IEC 60898. For domestic and commercial boards.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NB1-63H 2P B6 MCB, Double-Pole DIN Rail Circuit Breaker, Thermal-Magnetic Circuit Breaker
- Model: NB1-63H
- Rated Current: 6 A
- Number of Poles: 2P
- Rated Voltage: 230/400–240/415 V AC
- Rated Frequency: 50/60 Hz
- Breaking Capacity: 10 kA
- Tripping Curve: B curve, 3–5 times rated current
- Protection Type: Thermal-magnetic overload and short-circuit protection
- Insulation Voltage: 500 V
- Impulse Withstand Voltage: 4 kV
- Energy Limiting Class: 3
- Ingress Protection: IP20
- Terminal Capacity: Up to 25 mm²
- Connection: Top or bottom feed
- Mounting: 35 mm DIN rail to EN 60715
- Maximum Power Loss: 2 W per pole for 6 A rating
- Dimensions (H x L x W): 86mm x 78mm x 36mm
- Weight: 0.217 kg
- Double-pole switching and overcurrent protection
- 10 kA short-circuit breaking capacity
- B-curve tripping characteristic for resistive loads and longer cable runs
- Thermal-magnetic protection against overload and short-circuit currents
- Suitable for domestic, commercial and light industrial distribution boards
- DIN rail installation with top or bottom cable connection
- Compatible with selected auxiliary, alarm, shunt-release and undervoltage accessories
- Installation, testing and connection to mains electrical circuits must be performed by a licensed electrician in accordance with AS/NZS 3000, the switchboard manufacturer's requirements and applicable local regulations.
- Domestic distribution boards
- Commercial electrical switchboards
- Lighting and general-purpose final circuits
- Control panels and light industrial distribution systems
- Protection of circuits requiring B-curve overcurrent protection
- IEC/EN 60898-1 product standard
- AS/NZS 60898.1:2024 is the applicable Australian/New Zealand standard for AC miniature circuit-breakers of this type; verify current approval and marking requirements before installation
- AS/NZS 3000 applies to selection and installation within Australian electrical installations
- Modular DIN rail construction allows replacement of the individual protective device without replacing the complete switchboard assembly
- Metal and thermoplastic components can be separated for recycling at end of service life
- Long mechanical service life can reduce replacement frequency and associated material waste
- RoHS documentation is available for the NB1-63H product range
CHINT's general warranty policy states 27 months from the date of manufacture for other low-voltage apparatus sold through authorised channels, subject to the applicable sales contract and warranty terms.
Available through authorised CHINT distributors in Australia.