The NAMUR Cylinder Sensor is designed for precise position sensing in industrial automation, featuring a T-slot design and IP67 rating for dust and water
Sign in
Please login to continue to your account.
- Cylinder type: T-slot
- Switching output: NAMUR
- Output characteristic: Control current per NAMUR EN 60947-5-6
- Switching frequency: 1,000 Hz
- Electrical wiring: DC 2-wire
- Enclosure rating: IP67
- Ex area category: 1G, 1D
- Device labeling: II 1G Ex ia IIC T4 Ga, II 1D Ex ia IIIC T200 135°C Da
- Response sensitivity (typical): 2.8 mT
- Overrun distance (typical): 9 mm
- Hysteresis (typical): ≤ 0.5 mT
- Reproducibility: ≤ 0.1 mT
- Reverse polarity protection: Yes
- Short-circuit protection: Yes
- Status indicator LED: Yes
- Power-up pulse protection: Yes
- Ambient operating temperature: -25°C to +80°C
- Shock and vibration resistance: 30 g, 11 ms / 10-55 Hz, 1 mm
- EMC: According to EN 60947-5-2
- Connection type: Cable, 2-wire, ferrules, 3 m axial outlet
- Material housing: Plastic, PA12
- Cable material: PVC
- Input voltage max: 20 V
- Input power max: 100 mW
- Input current max: 60 mA
- Nominal voltage: 8.2 V DC
- Dimensions (H x L x W): 10mm x 24mm x 24mm
- Weight: 0.1 kg
- T-slot cylinder type compatible with various cylinder adapters
- NAMUR switching output with control current per EN 60947-5-6
- High switching frequency of 1,000 Hz
- IP67 rated enclosure for dust and water protection
- Intrinsic safety certified for Ex ia IIC T4 Ga and Ex ia IIIC T200 135°C Da
- Reverse polarity and short-circuit protection
- Status indicator LED for operational feedback
- Wide ambient operating temperature range from -25°C to +80°C
- Shock and vibration resistant (30 g, 11 ms / 10-55 Hz, 1 mm)
- Cable connection with 3 m axial outlet
- Installation should be performed by a qualified electrician familiar with intrinsic safety and hazardous area equipment standards.
- Industrial automation for position sensing
- Hazardous area applications requiring intrinsic safety
- Use with profile, tie rod, round body, dovetail groove cylinders
- Suitable for environments with shock and vibration
- AS/NZS 3000 – Wiring Rules (Electrical Installation)
- AS/NZS 3820 – Essential Safety Requirements for Electrical Equipment
- Low power consumption with maximum input power of 100 mW
- Durable plastic PA12 housing reduces material waste
- Long service life reduces replacement frequency and waste
Standard manufacturer warranty applies; please refer to SICK for specific terms.