Online UPS 10kVA 8kW 1Ph with 80x9Ah Batteries PowerSeries
PowerSeries GP online double conversion UPS features 10kVA 8kW, 1:1 single phase, 80x9Ah battery bank and generator compatibility. Ideal for critical loads.
Sign in
Please login to continue to your account.
Alternatively Known As: 10kVA Online UPS, 10kVA 1:1 Single-Phase UPS, PowerSeries GP UPS, Uninterruptible Power Supply
- Rated Capacity: 10kVA
- Rated Active Power: 8kW
- Topology: Online double conversion
- Input/Output Configuration: 1:1 single phase
- Battery Bank: 80 x 12V 9Ah sealed lead-acid batteries
- Battery Energy: Approximately 86.4kWh nominal across the complete battery bank
- Generator Compatibility: Supported
- Output Waveform: Pure sine wave, typical of online double-conversion UPS systems
- Application: Critical-load power protection
- Dimensions (H x L x W): 890mm x 850mm x 520mm
- Weight: 304 kg
- Continuous online double-conversion power conditioning
- 10kVA capacity with 8kW active-power rating
- Single-phase 1:1 input and output configuration
- Large 80-battery bank for extended backup capability
- Generator-compatible input
- Suitable for critical infrastructure and sensitive electronic loads
- Battery-backed operation during mains interruptions
- Sealed lead-acid battery technology for low-maintenance operation
- Installation, commissioning and battery connection should be performed by a suitably qualified electrician or UPS technician. Permanent connection should comply with AS/NZS 3000, with battery-system installation assessed against AS/NZS 5139 where applicable. Provide suitable ventilation, isolation, overcurrent protection, earthing and floor loading for the UPS and battery cabinet.
- Server rooms and data centres
- Telecommunications and network infrastructure
- Industrial control systems
- Security, monitoring and access-control systems
- Medical, laboratory and other critical electronic loads
- Commercial facilities requiring generator-compatible backup power
- AS IEC 62040.1: Uninterruptible power systems — general and safety requirements; product certification should be confirmed with the supplier
- AS/NZS 3000: Electrical installations — wiring and permanent electrical connection requirements
- AS/NZS 5139: Electrical installations — safety of battery systems for use with power conversion equipment, where applicable
- Sealed lead-acid batteries and associated metals can be recovered through established battery-recycling programs
- Online power conditioning can help protect sensitive equipment and reduce premature replacement caused by voltage disturbances
- Extended UPS service life can reduce electronic equipment waste and replacement frequency
- Generator compatibility can support efficient operation of backup power systems when correctly sized and managed
No manufacturer-specific POWERSERIES warranty policy was located. Confirm warranty duration, battery coverage, commissioning requirements and service conditions with the authorised Australian supplier before purchase.
Available through POWERSERIES and authorised Australian UPS distributors, subject to project configuration, battery availability and supplier confirmation.
UPS Sizing Calculator
This calculator follows relevant Australian standards to ensure reliable and compliant performance. It provides an estimated recommendation based on user inputs.
Users must verify specifications before purchasing.