- MTTFD (mean time to dangerous failure): 300 years (EN ISO 13849-1)
- Number of steps per revolution: 1,024 (10 bit)
- Measuring step: 360° / number of steps
- Measuring step deviation: 0.005° binary number of steps
- Error limits G: 0.035° (binary number of steps)
- Repeatability standard deviation σr: 0.005°
- Communication interface: Parallel data world
- Initialization time: 80 ms
- Code type: Binary
- Code sequence parameter adjustable: CW (clockwise) increasing when viewing the clockwise rotating shaft
- Measured value backlash: 0.005°
- Response threshold: 0.003°
- Connection type: Cable, 22-wire, radial, 3 m
- Supply voltage: 10 to 32 V
- Operating current: Typically 90 mA
- Switching level of control inputs: Logic H = 0.7 x U_S, Logic L = 0 V to 0.3 x U_S
- Actuation of set button: ≥ 100 ms
- Mechanical design: Through hollow shaft
- Shaft diameter: 12 mm
- Characteristics of the shaft: Front clamp
- Housing material: Aluminum die cast
- Start up torque: Typically 2.2 Ncm
- Operating torque: Typically 1.6 Ncm
- Permissible movement static: ± 0.3 mm (radial), ± 0.5 mm (axial)
- Permissible movement dynamic: ± 0.1 mm (radial), ± 0.2 mm (axial)
- Operating speed: ≤ 3,000 min⁻¹
- Bearing lifetime: 3.6 x 10^9 revolutions
- Angular acceleration: ≤ 500,000 rad/s²
- EMC: According to EN 61000-6-2 and EN 61000-6-3
- Enclosure rating: IP64 (cable IEC 60529)
- Permissible relative humidity: 90% (no condensation)
- Operating temperature range: -20°C to +85°C
- Storage temperature range: -40°C to +100°C (without package)
- Resistance to shocks: 50 g, 11 ms (EN 60068-2-27)
- Resistance to vibration: 20 g, 10 Hz to 2,000 Hz (EN 60068-2-6)
- Dimensions (H x L x W): 60mm x 60mm x 60mm
- Weight: 0.3 kg
- High resolution with 1,024 steps per revolution (10 bit)
- Through hollow shaft design with 12 mm shaft diameter
- Robust aluminum die cast housing
- IP64 rated enclosure for dust and splash protection
- Operating temperature range from -20°C to +85°C
- Low start-up torque of typically 2.2 Ncm
- High mechanical durability with bearing lifetime of 3.6 x 10^9 revolutions
- Fast initialization time of 80 ms
- Parallel data communication interface
- Certified with multiple international conformity declarations including EU, UK, ACMA, cULus
- Installation should be performed by qualified personnel familiar with electrical and mechanical integration of rotary encoders to ensure proper alignment and connection.
- Industrial automation for precise position measurement
- Robotics requiring accurate angular feedback
- Machine tools and manufacturing equipment
- Safety-related systems requiring reliable encoder data
- AS/NZS 3000 – Wiring Rules (Electrical Installation)
- Durable design reduces replacement frequency and electronic waste
- Low power consumption with typical operating current of 90 mA
- Compliance with RoHS regulations limits hazardous substances