Safety OSSD Module SIL 3 & Category 4 Dual-Channel Outputs SICK
The Safety OSSD Module FLN-OSSD1000105 is designed for high-integrity safety monitoring in industrial applications.
Sign in
Please login to continue to your account.
- Safety integrity level: SIL 3 (IEC 61508)
- Category: Category 4 (EN ISO 13849)
- Performance level: PL e (EN ISO 13849)
- Mean probability of dangerous failure per hour (PFHD): 0.76 x 10^-9
- Mission time: 20 years
- Connection type: Female M12 5-pin for safety device, Male M12 5-pin for Flexi Loop input, Female M12 5-pin for Flexi Loop output
- Number of non-safe inputs: 1
- Power supply output: 24 V DC (16.8 V DC to 30 V DC), max 3.9 A
- Power consumption: 45 mA
- Input voltage for OSSD inputs: HIGH 13 V DC to 30 V DC, LOW -5 V DC to 5 V DC
- Input current for OSSD inputs: HIGH 3.5 mA to 6.2 mA, LOW -2.5 mA to 2.5 mA
- Switching voltage for non-safe inputs: HIGH 13 V DC to 30 V DC, LOW 0 V DC to 5 V DC
- Input current for non-safe inputs: ≤ 6.2 mA
- Protection class: III (EN 61140)
- Enclosure rating: IP65 and IP67 (EN 60529)
- Operating temperature: -25 °C to +55 °C
- Storage temperature: -25 °C to +70 °C
- Dimensions (H x L x W): 48mm x 18mm x 68mm
- Weight: 0.1 kg
- Safety integrity level SIL 3 (IEC 61508)
- Category 4 (EN ISO 13849) and Performance level PL e (EN ISO 13849)
- Diagnostic and monitoring functions including cross-circuit, short-circuit, discrepancy and sequence error monitoring
- Dual-channel OSSD outputs for safety sensor connection
- Flexi Loop input and output connectors for flexible safety network integration
- Power supply output for external devices up to 3.9 A
- Protection class III with PELV or SELV supply voltage
- Enclosure rated IP65 and IP67 for robust environmental protection
- Operating temperature range from -25 °C to +55 °C
- Installation should be performed by qualified personnel familiar with safety systems and electrical standards to ensure compliance and optimal performance.
- Industrial safety systems requiring high integrity safety monitoring
- Machine safety with dual-channel OSSD outputs
- Integration with Flexi Soft safety controllers in automated environments
- AS/NZS 4801 – Occupational Health & Safety Management Systems
- Enhances machine safety reducing risk of accidents and associated environmental hazards
- Durable IP65/IP67 rated enclosure reduces waste from frequent replacements
- Low power consumption design supports energy efficiency in industrial applications
Standard manufacturer warranty applies. Please refer to SICK for detailed warranty terms.
The SICK FLN-OSSD1000105 safety device is available for immediate purchase, ideal for industrial safety and automation applications requiring high reliability and diagnostic capabilities.