Ultrasonic Fluid Level Sensor Switch & Continuous Measurement IP67 Rated SICK
The Ultrasonic Fluid Level Sensor UP56-211156S01 offers precise switch and continuous level measurement for fluids, making it ideal for industrial process control.
Sign in
Please login to continue to your account.
- Medium: Fluids
- Measurement: Switch and continuous
- Measuring range in tank: 30 mm to 250 mm
- Measuring range immersion tube: 30 mm to 500 mm
- Process pressure: 0 bar to 2 bar
- Process temperature: -25 °C to +85 °C
- Accuracy of sensor element: ≤ 1%
- Reproducibility: ± 0.15%
- Resolution: 0.025 mm
- Response time: 68 ms
- MTTF: > 100 years
- Supply voltage: 9 V DC to 30 V DC
- Residual ripple: ± 10%
- Power consumption: ≤ 80 mA
- Protection class: III
- Connection type: 5-wire shielded PVC cable, 10 m length
- Output signal: 4 mA to 20 mA
- Hysteresis: 3 mm
- Output current: 200 mA
- Time delay before availability: ≤ 300 ms
- Enclosure rating: IP67
- Ultrasonic frequency: 320 kHz
- Ultrasonic transducer coating: PTFE, FFKM
- Wetted parts: PTFE, FFKM
- Process connection: GF connection D40
- Housing material: Polypropylene (PP)
- Housing design: Compact
- Dimensions (H x L x W): 100mm x 100mm x 40mm
- Weight: 0.145 kg
- Measurement types: Switch and continuous level measurement
- Measuring range in tank: 30 mm to 250 mm
- Measuring range immersion tube: 30 mm to 500 mm
- Process pressure range: 0 bar to 2 bar
- Process temperature range: -25 °C to +85 °C
- High accuracy sensor element with ≤ 1% accuracy
- Reproducibility of ± 0.15%
- Fast response time of 68 ms
- Long mean time to failure (MTTF) greater than 100 years
- Output signal: 4 mA to 20 mA
- Protection rating IP67 for dust and water resistance
- Compact housing made of polypropylene (PP)
- Wetted parts made of PTFE and FFKM for chemical resistance
- 10 m shielded PVC connecting cable with flying leads
- Installation should be performed by qualified personnel familiar with ultrasonic sensor technology and electrical safety standards to ensure proper setup and compliance.
- Fluid level measurement in tanks and containers
- Industrial process control involving liquids
- Continuous and switch level detection in fluid systems
- Complies with AS/NZS 4801 – Occupational Health & Safety Management Systems
- Non-contact ultrasonic measurement reduces contamination risk and maintenance needs
- Durable materials extend product life, reducing waste
- Low power consumption of ≤ 80 mA supports energy efficiency
Standard manufacturer warranty applies; please refer to SICK's official warranty policy for details.
The SICK UP56-211156S01 Ultrasonic Fluid Level Sensor is available for immediate purchase, ideal for industrial fluid level monitoring and control applications.