TLON is a local network that uses LonWorks® technology.

The FT512 control units are connected to the TLON network with a built in module, the TLON connection board 1590. Up to 30 nodes (i.e. FT512 c.i.e:s) can be connected to a TLON Network. One of the nodes can bean external PC with a software driver for a Security Management system, which gives full control of and access to all data in all FT512 connected to the network.


Call 02 9150 7744 For the BEST DEAL  
In stock

Firetracker FT1020G3 is an intelligent analogue addressable fire system, conforming to the AS7240.2 Control and Indicating Equipment, AS7240.4 Power Supply and AS4428.3 - 2010 Fire Brigade Panel standards. FT1020G3 is the third generation of Brooks intelligent analogue addressable systems. It meets the most stringent requirements in order to secure real fire alarms and to reduce nuisance alarms.


Call 02 9150 7744 For the BEST DEAL  
In stock

Description

Firetracker FT128V2 is an intelligent analogue addressable fire alarm system, conforming to the AS7240-2 Control and Indicating Equipment, AS7240-4 Power Supply, AS4428.3 Fire Brigade Panel standards and NZS4512. It meets the most stringent requirements in order to secure real fire alarms and to reduce nuisance alarms.



Call 02 9150 7744 For the BEST DEAL  
In stock

Each fan control module consists of a universal I/O matrix PCB specifically configured for fan control applications. Programming is simplified through the Win512 configuration software.


Call 02 9150 7744 For the BEST DEAL  
In stock

The External Presentation Unit 1728 is a compact sized enclosure rated to IP61 (if fitted with the supplementary “O” ring gasket). The unit is intended for pre-warning, co-incidence, fire (and heavy smoke/heat) alarm presentation. If there are two or more alarms in the system, the operator can scroll amongst them but the alarms cannot be reset via this unit. There is no front panel door which means the unit can be accessed directly when required. The push buttons are disabled until they are supposed to be used.


Call 02 9150 7744 For the BEST DEAL  
In stock

In each control unit there can be, in total, up to six expansion boards of all types mounted.

Up to six 1580 boards can be used.

Each board has to be programmed (Win512) regarding:
- Address
- Address is set with jumpers on the board

This board has eight inputs for conventional zone lines.

In the last unit on each zone line an end-of-line resistor (4K7) has to be connected.


Call 02 9150 7744 For the BEST DEAL  
In stock

In each control unit there can be, in total, up to six expansion boards of all types mounted.


Call 02 9150 7744 For the BEST DEAL  
In stock

In each control unit there can be, in total, up to six expansion boards of all types mounted.

Up to TWO 1587 boards can be used.

Because of high components on the board, a 1587 board always has to be mounted "on top".

Each board has to be programmed (Win512) regarding:
- Address (= set with jumpers on the board, i.e. 0 or 1)
- Name (Default is DU 1587, which is normally not changed)

This board is an interface only for Presentation unit 1728 and Alert annunciation Units 1736 running in S/W mode 2.3.2 or greater

The data rate in this mode is 9600 baud.

The theoretical number of units that can be connected to the board is sixteen but it is depending on the type and the number of the units respectively, the cable type and length, etc.


Call 02 9150 7744 For the BEST DEAL  
In stock

Web-Server II has a plastic cabinet, which is vertically mounted on a symmetric 35mm Din Rail. Web-Server shall be mounted inside FT512 or FT128 cabinets. A cable and accessories kit for both systems is supplied with the Web-Server II


Call 02 9150 7744 For the BEST DEAL  
In stock

The Zone Control Module provides a simplified indication of zone status without the need for a liquid crystal display. The disable control allows a specific zone to be temporarily disabled without the need to access the CIE menu. This is typically used where building works or maintenance procedures are being carried out in a localised area of a building.