Matchmaster has a complete range of PAY TV and FTA approved cables for both commercial and residential applications. Matchmaster s range includes standard, flooded, messengered, Tri-Shield and Quad Shield RG6 and RG11 cable. Also available in White approved RG6 Quad Shield cable for indoor use. Whatever the application Matchmaster has the cable to suit.View More Coaxial Cable
An RG11 metre marked cable with quadshield and floodedGel filled Cable designed for underground useSuitable and approved for Pay and Digital TVSold in a 305 metre reelFoxtel (F30445), Telstra (739/10) and NBN approved
Construction
Inner Conductor:Material:Copper Clad Steel Wire
Diameter, mm:1.63±0.015
Insulation:Material:Physically Foamed PE
Diameter, mm:7.11±0.15
Outer Conductor:1st shield:Bonded Al/PET/Al Tape 7.32 ±0.15
2nd shield:Al-Mg Alloy Wire Braid
3rd shield:Non-bonded Al/PET/Al Tape
4th shield:Al-Mg Alloy Wire Braid
Jacket:Material:PE
Diameter, mm:10.34±0.20
Mechanical Properties
Bending Radius, mm:Single:50
Typical:100
Pulling Strength, N:384
Adhesion Force, N:>60
Electrical Properties
Impedance, Ω:75±3
DCR of Inner conductor, Ω /km:40.40
DCR of outer conductor, Ω /km:14.40
Capacitance, pF/m:54
Propagation Velocity, %:82
DC Breakdown Voltage, kV:6.0
Insulation Resistance, MΩ ¢km:>1Ã104
Screening Attenuation, dB:>105@5~1000MHz
>95@1000~2000MHz
>85@2000~3000MHz
Attenuation
Frequency:MHz:Max. attenuation @20â,dB/100m
5MHz:1.25
55MHz:3.15
211MHz:6.23
250MHz:6.72
270MHz:7.00
300MHz:7.38
330MHz:7.71
350MHz:7.94
400MHz:8.53
450MHz:9.02
500MHz:9.51
550MHz:9.97
600MHz:10.43
750MHz:11.97
870MHz:13.31
1000MHz:14.27
1300MHz:16.21
1450MHz:17.36
1750MHz:19.52
2150MHz:21.65
2600MHz:24.04
2832MHz:25.09
3000MHz:25.86
Return Loss, dB
5-3000MHz: 20
Standards
Operation:-40~+70°C
UL 1581 UV Resistance 720h:Compliant
2011/65/EU:Compliant
An RG11 metre marked cable with quadshield and floodedGel filled Cable designed for underground useSuitable and approved for Pay and Digital TVSold in a 305 metre reelFoxtel (F30445), Telstra (739/10) and NBN approved
Construction
Inner Conductor:Material:Copper Clad Steel Wire
Diameter, mm:1.63±0.015
Insulation:Material:Physically Foamed PE
Diameter, mm:7.11±0.15
Outer Conductor:1st shield:Bonded Al/PET/Al Tape 7.32 ±0.15
2nd shield:Al-Mg Alloy Wire Braid
3rd shield:Non-bonded Al/PET/Al Tape
4th shield:Al-Mg Alloy Wire Braid
Jacket:Material:PE
Diameter, mm:10.34±0.20
Mechanical Properties
Bending Radius, mm:Single:50
Typical:100
Pulling Strength, N:384
Adhesion Force, N:>60
Electrical Properties
Impedance, Ω:75±3
DCR of Inner conductor, Ω /km:40.40
DCR of outer conductor, Ω /km:14.40
Capacitance, pF/m:54
Propagation Velocity, %:82
DC Breakdown Voltage, kV:6.0
Insulation Resistance, MΩ ¢km:>1Ã104
Screening Attenuation, dB:>105@5~1000MHz
>95@1000~2000MHz
>85@2000~3000MHz
Attenuation
Frequency:MHz:Max. attenuation @20â,dB/100m
5MHz:1.25
55MHz:3.15
211MHz:6.23
250MHz:6.72
270MHz:7.00
300MHz:7.38
330MHz:7.71
350MHz:7.94
400MHz:8.53
450MHz:9.02
500MHz:9.51
550MHz:9.97
600MHz:10.43
750MHz:11.97
870MHz:13.31
1000MHz:14.27
1300MHz:16.21
1450MHz:17.36
1750MHz:19.52
2150MHz:21.65
2600MHz:24.04
2832MHz:25.09
3000MHz:25.86
Return Loss, dB
5-3000MHz: 20
Standards
Operation:-40~+70°C
UL 1581 UV Resistance 720h:Compliant
2011/65/EU:Compliant