- Medium: Fluids
- Measurement type: Switch
- Probe length: 115 mm
- Process pressure range: -1 bar to 64 bar
- Process temperature range: -40 °C to +100 °C
- Fill material density range: 0.7 g/cm³ to 2.5 g/cm³
- Sensor accuracy: ± 2 mm
- Reproducibility: ≤ 1 mm
- Viscosity range: 0.1 mPas to 10,000 mPas
- Resolution: ≤ 1 mm
- Response time: 500 ms
- Mean time between failures (MTBF): 1.25×10^7 hours
- Supply voltage: 20 V AC/DC to 253 V AC/DC
- Power consumption: ≤ 10 mA
- Initialization time: < 3 seconds
- Connection type: Valve plug DIN 43650
- Output signal: Non-contact switch
- Hysteresis: 2 mm
- Inductive load: ≤ 1 H
- Capacitive load: 100 nF
- Enclosure rating: IP65
- Temperature drift: 0.03 mm/K
- Wetted parts material: Stainless steel 1.4404 / 316L
- Process connection: G 1 A PN 64
- Housing material: Stainless steel 1.4404 / 316L, PEI
- Ambient operating temperature: -40 °C to +70 °C
- Storage temperature: -40 °C to +80 °C
- Dimensions (H x L x W): 150mm x 115mm x 50mm
- Weight: 0.5 kg
- Tuning fork probe type for reliable fluid level measurement
- Wide process pressure range from -1 bar to 64 bar
- Operates in process temperatures from -40 °C to +100 °C
- High accuracy with ±2 mm sensor element precision
- Fast response time of 500 ms
- Robust stainless steel 1.4404 / 316L wetted parts and housing
- IP65 rated enclosure for protection against dust and water
- Non-contact switch output signal for reliable switching
- Wide supply voltage range from 20 V AC/DC to 253 V AC/DC
- VDE protection class 1 certified
- Installation should be performed by a qualified technician or electrician familiar with process instrumentation and electrical safety standards.
- Fluid level detection in industrial tanks and vessels
- Process control in chemical, food, and pharmaceutical industries
- Monitoring liquids with varying viscosities and densities
- AS/NZS 3000 – Wiring Rules (Electrical Installation)
- Non-contact switching reduces wear and extends product life, minimizing waste
- Energy-efficient operation with low power consumption (≤ 10 mA)
- Durable stainless steel construction reduces need for frequent replacements
Standard manufacturer warranty applies. Please refer to SICK's official warranty policy for details.
The SICK LFV200-XASGACPVL tuning fork level switch is available for immediate purchase, ideal for fluid level measurement in industrial and process control applications.