7 - 10 Amp Dual Pump Controller - Standard With Start & Run Capacitors - Single Phase

FPC-30022-C

Call 02 9150 7744 For the BEST DEAL

Matelec-7 - 10 Amp Dual Pump Controller - Standard With Start & Run Capacitors - Single Phase
Product Features
Enclosure:
IP56 weatherproof rating
Powder coated mild steel
Inner door and removable gland plate
Protection:
Padlockable mains power isolator switch
Circuit breaker protected low voltage control and input circuitry
Individual pump isolation
Contactor and thermal overload protection of pumps
Electronic short and overload protection of strobe/buzzer
Alarms:
Visual (strobe) and audible (buzzer) alarms
Control & interface:
Electronic Keypad
Indicator lights for power on, level alarm, pump run/fault
Visual and audible alarm mute/reset/test button
Auto/off/manual operation of pumps
Dipswitches for input and operation configuration
User adjustable timer for start capacitor switching
Inputs:
4x digital 12Vdc inputs for float/pressure/flow switches
Standard terminal setup: Low level, pump stop, pump start and high level float switches
Outputs:
2x pump supply outputs
1x BMS volt free output for common fault
Included with panel:
Start capacitor (30μF) and run capacitor (145 - 175μF)
Function Features
Operation:
Maximum run timer and auto alternation of pump duty
Anti seize timer runs pumps periodically during low use
Optional time out on manual pump mode
Maximum idle time ensures minimum tank level is maintained
Staggered pump start
Level alarm delay avoiding nuisance alarms
Smart auto silencing and chirp mode alarm
Fault protection:
Pump overload shut-down
High level alarm
Low level alarm and shut-down
Low pressure alarm and shut-down (with pressure switch)
Low flow/prime loss shut-down (with flow switch)
Optional maximum pump run time shut-down
Optional Modifications
316 stainless steel enclosure
Generator input socket and automatic changeover
Battery backup high level alarm
4G SMS alarm sender
Conductivity relays and probe inputs
Alternative capacitor sizes
Common Applications
Level Control:
Submersible sewage
Submersible storm water
Transfer pumping
Pressure control:
Pressure boosting
FPC-30022 Range - Single Phase (230Vac)
Code
Overload Rating
Enclosure Size
FPC-30022-AA
1.6 - 2.5 Amp
500x500x200mm
FPC-30022-A
2.5 - 4 Amp
500x500x200mm
FPC-30022-B
4 - 6 Amp
500x500x200mm
FPC-30022-BB
5.5 - 8 Amp
500x500x200mm
FPC-30022-C
7 - 10 Amp
500x500x200mm
FPC-30022-D
9 - 13 Amp
500x500x200mm
FPC-30022-E
12 - 18 Amp
500x500x200mm
Other Overload Ratings available on request

ImageandDatasheet/FPC_30022.pdf (ImageandDatasheet/FPC_30022.pdf, 0) [Download]

FPC_30022.pdf (FPC_30022.pdf, 311 Kb) [Download]

Good to know