90 kW Advanced - With BMS Soft Starter - Dual Pump

FPC-36240-S90

Call 02 9150 7744 For the BEST DEAL

Matelec-90 kW Advanced - With BMS Soft Starter - Dual Pump
Product Features
Enclosure:
IP56 weatherproof rating
Powder coated mild steel
Inner door and removable gland plate
Protection:
Padlockable mains power isolator switch
Circuit breaker protected low voltage control and input circuitry
Individual pump isolation
Contactor and thermal overload protection of pumps
Electronic short and overload protection of strobe/buzzer
Alarms:
Visual (strobe) and audible (buzzer) alarms
Control & interface:
Advanced HMI with backlit LCD screen & navigation keys
System and pump status overview
Auto/off/manual operation of pumps
Alarm display screen and mute button
Logged data for start & fault counters, pump run hours
Input configuration and parameter adjustment
Tank/pit level display (with transducer connected)
Password protection
User adjustable soft start and soft stop
Inputs:
1x analogue 4-20mA input for hydrostatic transducer
4x digital 24Vdc inputs for float/pressure/flow switches
Standard terminal configuration: Low level, pump stop, pump start and high level float switches
Outputs:
BMS volt free outputs for system fault, power on, high level, individual pump run and fault
Optional modbus RS485 connections
Function Features
Operation:
Maximum run timer and auto alternation of pump duty
Anti seize timer runs pumps periodically during low use
Optional time out on manual pump mode
Maximum idle time ensures minimum tank level is maintained
Staggered pump start and stop
Pump limiting allows only 1 pump to run at a time
Static lead pump for applications with low average flows but high peak flows
Level alarm delay avoiding nuisance alarms
Current loop reverse operation for maintain pressure or emptying, rather than filling, a tank
Smart auto silencing and chirp mode alarm
Fault protection:
Pump overload shut-down
High level alarm
Low level alarm and shut-down
Low pressure alarm and shut-down (with pressure switch)
Low flow/prime loss shut-down (with flow switch)
Optional maximum pump run time shut-down
Optional transducer fault alarm (with transducer)
Optional Modifications
316 stainless steel enclosure
Free standing enclosure with plinth
Separate compartment for power authority meters
Generator input socket and automatic changeover
Battery backup high level alarm
4G SMS alarm sender
Conductivity relays and probe inputs
Mains bypass or tank top up control with solenoid valve
Common Applications
Level Control:
Submersible sewage
Submersible storm water
Transfer pumping
Pressure control:
Pressure boosting
FPC-36240-S Range - Three Phase (400Vac)
Code
Power Rating
Enclosure Size
FPC-36240-S4.0
4.0 kW
500x500x300mm
FPC-36240-S5.5
5.5 kW
500x500x300mm
FPC-36240-S7.5
7.5 kW
500x500x300mm
FPC-36240-S11
11 kW
500x500x300mm
FPC-36240-S15
15 kW
500x500x300mm
FPC-36240-S22
22 kW
600x600x300mm
FPC-36240-S30
30 kW
600x600x300mm
FPC-36240-S37
37 kW
600x600x300mm
FPC-36240-S45
45 kW
800x600x300mm
FPC-36240-S55
55 kW
800x600x300mm
FPC-36240-S75
75 kW
800x800x300mm
FPC-36240-S90
90 kW
800x800x300mm
Additional Power Ratings up to 160 kW available on request

ImageandDatasheet/MatelecCatalogue.pdf (ImageandDatasheet/MatelecCatalogue.pdf, 0) [Download]

MatelecCatalogue.pdf (MatelecCatalogue.pdf, 12,133 Kb) [Download]